TM 799200 Rev (C), January 2014
Models and Types 9
2.5 Models and Types
Series 700S offers 2 families of detected gases:
Models 701S, 702S and 703S used for methane, LPG and gases mixture
for most offshore and onshore applications.
Models 721S, 722S and 723S used for ethylene only.
Table 3 describes the installation distances for each of the Series 700S
models.
Table 3: Model Numbers and Installation Distances
Min.
Installation
Distance
Max.
Installation
Distance
The 700S Series has 3 wiring options:
Option 1: Power, Alarm Relay, Fault Relays, 0-20mA
Option 2: Power, Alarm Relays, Fault Relays, Accessory Relay
Option 3: Power, Alarm Relay, RS-485, 0-20mA, RS-485 RTN (default)
Note: SIL2 covers only 0-20mA outputs.
The wiring option must be set at the factory; cannot be changed at
customer facility.