22 Environmental Specifications
4.4 Environmental Specifications
The SafEye system is designed to withstand harsh environmental conditions.
The source and detector units compensate for adverse conditions while
maintaining accuracy.
4.4.1 High Temperature
Designed to meet MIL-STD-810C, method 501.1 procedure II.
Operating Temperature:
+149 ºF (+65 ºC)
Storage Temperature:
+149 ºF (+65 ºC)
4.4.2 Low Temperature
Designed to meet MIL-STD-810C, method 502.1, procedure I
Operating Temperature:
-4 ºF (-20 ºC)
Storage Temperature:
-40 ºF (-40 ºC)
4.4.3 Humidity
Designed to meet MIL-STD-810C, method 507.1, procedure IV
relative humidity of up to 95% for the operational temperature range.
4.4.4 Salt and Fog
Designed to meet MIL-STD-810C, method 509.1 procedure I.
Exposure to a 5% salt solution for 48 hours.
4.4.5 Water and Dust
IP67 per EN60529
IP66 per EN60529
Dust:
Totally protected against dust
Liquids:
Protected against immersion between 15
cm and 1m in depth. Protected against
all water jets from all directions.
4.4.6 Shock and Vibration
Vibration:
Designed to meet MIL-STD-810C,
method 514.2, procedure VIII.
Mechanical Shock:
Designed to meet MIL-STD-810C,
method 516.1, procedure I.